{"product_id":"intellijel-tangrams","title":"INTELLIJEL TANGRAMS","description":"\u003cp data-mce-fragment=\"1\"\u003eTangrams, like our Dual ADSR before it, is a dual analog core-envelope inspired by the Roland SH-101 \/ System 100m design with several enhancements. Taking further inspiration from trapezoidal function generators like the one on the EMS Synthi, we have added a voltage-controlled pulser circuit to link the triggering of two envelopes - allowing for delayed one-shots, cycling organic envelopes, and more. In addition, we've added two VCAs for level control of each envelope, or alternatively, direct injection of the signal you'd like to envelope - freeing up your other VCAs.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThe Pulser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Pulser can be thought of as a way to set both a gate ON time (T1) and an OFF time (T2). In this way, you could configure a cycling ADSR that has a gate time that is different from the interval between gates. Alternatively, you can create a sequence where ADSR2 is triggered by a delayed amount of time after ADSR1 is triggered (either cyclically or in a single shot sequence). The panel switches for routing or disabling the pulse sources allow for even more complex combinations of control beyond these examples. This special combination of functions can yield a plethora of interesting and organic envelope and gate patterns to be created; cyclical and single shot.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eADSR + VCA Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDual Analog ADSR envelopes with digital gate Pulser for trapezoid shapes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePulser stages P1 and P2 can be selectively routed to trigger each ADSR via panel switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThree timing ranges: (FAST: ~5 seconds, MED: ~35sec, SLOW: ~1min A\/D times)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eRetrig input (allows re-triggering of the envelope if source gate held high)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVCA input can be used to dynamically control the respective ADSR output level (bipolar) or to process signals to be modulated in amplitude by the ADSR.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eManual GATE buttons for each envelope\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePulser Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA pulse is made of individually controllable T1 and T2 stage lengths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCV control over T1 and T2 time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePulser can be one-shot (SINGLE) or repeating (CYCLE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePULSE output has a switch to select P1 or P2 as the source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePulser stages P1 and P2 can be selectively routed to trigger each ADSR via panel switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSTART trigger input for starting\/restarting the Pulser sequence\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eManual GATE button to trigger the Pulser sequence\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003eDimensions\u003c\/dt\u003e\n\u003cdd\u003e14 HP\u003c\/dd\u003e\n\u003cdd\u003e35 mm deep\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003eCurrent Draw\u003c\/dt\u003e\n\u003cdd\u003e66 mA +12V\u003c\/dd\u003e\n\u003cdd\u003e49 mA -12V\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"INTELLIJEL","offers":[{"title":"Default Title","offer_id":42315914117293,"sku":"","price":239.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3449\/7197\/files\/tangrams.jpg?v=1690825434","url":"https:\/\/www.detroitmodular.live\/products\/intellijel-tangrams","provider":"Detroit Modular","version":"1.0","type":"link"}